The depth can be 54 min.
Ada door pull requirements.
Door openings shall provide a clear width of 32 inches 815 mm minimum.
Handles pulls panic bars.
Ada standards for accessible design can be downloaded from www ada.
ü sliding or swing door hardware must not require more than 5 pounds of force to operate.
Hinge side approaches a side approach toward the hinge side of the door to the pull side of swinging doors shall have maneuvering space that extends 36 inches 915 mm minimum beyond the latch side of the door if 60 inches 1525 mm minimum is provided perpendicular to the doorway or maneuvering space that extends 42 inches 1065 mm minimum beyond the latch side of the door if 54 inches 1370 mm minimum is provided perpendicular to the doorway.
If the forward reach to operable parts extends over an obstruction such as a counter clearances for toes and knees is required below.
In general the requirements are a minimum of 32 in width and a maximum of 48 and the door must open to 90 degrees.
Clear width is measured from the face of the door to the stop when the door is fully opened at 90 degrees.
For more information for information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
Doors designated as fire doors must have the minimum opening force allowed by the local authority.
If clear floor space is obstructed on both sides more than half the minimum required depth a wider clearance 36 min is required for maneuvering and sway.
Thresholds 404 2 5 thresholds cannot be any higher than and should be slip resistant.
Latch side clearance is required if the depth is 60 min.
Door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
ü the pull handle must be operable with one hand limb without tight grasping pinching or twisting of the wrist.
Also state or local government codes may have specific accessibility requirements for exterior doors.
A minimum of 10 inches is required from the bottom of pull handle to the finished floor on the corridor side.
The ada standards do not specify the opening force for exterior doors though some state and local building codes may have requirements.
If the latch side clearance is at least 42.
Section 404 of the ada states.
Typical maximum opening force for exterior doors ranges from 8 5 to 10 lbs.
On the pull side of hinge approaches 36 min.
Space at least 60 deep in front of a door will accommodate a forward approach except in case of hinge approaches on the pull side.
Or for answers to specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383 tty.
In order for wheelchairs to have clear passage through your doors at a minimum your clear opening width must be 32 wide.
Typical maximum opening force for exterior doors ranges from 8 5 to 10 lbs.